Home Services Facilities & Maintenance
Operations & Maintenance Division

Maximizing Asset Lifecycle with Preventative Operations & Uptime

Operating continuously since 1990, Skycom Infrastructure delivers round-the-clock technical operations, predictive thermal diagnostics, scheduled equipment audits, and rapid emergency restoration teams to safeguard critical asset uptime.

Predictive Infrared Thermography & Health Checks
Non-invasive FLIR thermal scanning identifying high-resistance electrical hot spots, loose busbars, and solar string hotspots before failure occurs.
24/7 Rapid Emergency Response & Fiber Splicing
Dispatched technical vans equipped with OTDRs, fusion splicers, hydraulic tools, and replacement components for immediate fault clearing.
Facilities Engineers Performing Electrical Thermographic Scans by Skycom
24/7 Rapid Response Squads
FLIR Thermography Certified
Operational Maintenance Framework

The Proactive Asset Maintenance Path

Select any maintenance lifecycle phase below to inspect diagnostic tools, frequency, and SLA deliverables.

Step 01
Asset Onboarding
Tagging & Baseline Audit
Step 02
IR Diagnostics
Thermography & Earth Tests
Step 03
Scheduled PM
Torque, Clean & Lubricate
Step 04
24/7 Dispatch
Under 2-Hour Response
Step 05
Performance Tuning
Solar I-V & OTDR Tests
Step 06
SLA Reporting
Audit Logs & Analytics

Step 01: Comprehensive Asset Registry & Baseline Health Audit

QR-code asset tagging, single-line diagram verification, baseline insulation tests, and full integration into the digital CMMS maintenance software platform.

  • Asset Tagging: Durable Metal QR / RFID Barcodes
  • CMMS Software: Cloud-Connected Digital Work Orders
  • Electrical Audit: Insulation Resistance Megger Baseline
  • Inspection Output: Asset Health Index & Risk Register
Operations Scope

Proactive & Predictive Maintenance

We provide specialized preventive maintenance contracts designed to prevent equipment downtime, reduce operating costs, and extend asset life.

Switchgear & Substation O&M

High-voltage transformer oil testing, vacuum circuit breaker servicing, earth pit resistance audits, and thermal hotspot detection.

  • Transformer BDV & DGA oil analysis
  • Contact resistance & breaker trip timing
  • Earth electrode resistance (<1.0 Ohm) audits
Request Electrical Scope

Fiber & Network Health AMC

Scheduled OTDR link attenuation tests, fiber patch cable re-dressing, transceiver diagnostics, and emergency fiber cut restoration squads.

  • Bi-directional OTDR power trace logs
  • Patch panel ferrule end-face microscopic cleaning
  • Fast fusion splice repair on emergency cut calls
Request Network AMC

Solar Cleaning & Generation O&M

De-mineralized robotic/manual module washing, string voc/isc measurements, inverter heat-sink cleaning, and drone thermal hotspot scanning.

  • Bi-weekly / monthly automated de-mineralized cleaning
  • String I-V curve testing & diode check
  • Guaranteed solar performance ratio (>80% PR)
Request Solar O&M Scope

HVAC & Central Mechanical Plant

Chiller condenser descaling, AHU belt tensioning, air filter replacement, refrigerant pressure audits, and BMS actuator calibration.

  • Chiller tube eddy-current testing & descaling
  • Motor vibration & bearing lubrication analysis
  • Indoor air quality (IAQ) filter replacements
Request HVAC Scope
Testing Instrumentation

Industrial Diagnostic Instruments

Our engineers utilize calibrated, industry-standard diagnostic tools to identify invisible stress points and prevent unpredicted component breakdown.

FLIR Infrared Thermal Imagers

High-definition radiometric thermal sensors capturing temperature differentials across high-voltage busbars, breakers, and solar modules.

Thermal Sensitivity< 0.04°C @ +30°C NETD
IR Resolution320 x 240 True Pixels
ReportingRadiometric Thermal PDF Logs

Fluke Insulation & Earth Testers

Digital 5kV insulation resistance testers and 4-pole earth resistance meters ensuring compliance with IS 3043 grounding standards.

Test VoltageUp to 5,000V DC (Megger)
Earth Resistance0.01 Ohm Resolution (IS 3043)
CalibrationNABL Accredited Calibration

Solar PV I-V Curve Analyzers

Precision 1500V / 30A I-V curve tracers with wireless irradiance and temperature sensors to measure real-time degradation and fill factor.

Max Voltage1,500V DC String Testing
Irradiance SensorReference Cell Pyranometer
ParametersVoc, Isc, Pmax, Fill Factor (FF)

EXFO Optical Test Sets

Optical time-domain reflectometers (OTDR), optical power meters (OPM), and fiber visual fault locators (VFL) for link troubleshooting.

Wavelengths1310nm / 1550nm Dual-Band
Fault DetectionMicro-bends & Fiber Breaks
Report SpecTIA Tier-2 Event Map

Vibration Spectrum Analyzers

Triaxial accelerometers monitoring vibration velocity and bearing health on major pumps, cooling tower fans, and diesel generators.

StandardISO 10816 Mechanical Vibration
SamplingFast Fourier Transform (FFT)
Bearing PeakDemodulation Envelope Peak

Ultrasonic Gas Leak Detectors

High-frequency acoustic cameras and ultrasonic transducers locating micro-leaks in chiller refrigerant circuits and compressed air lines.

Frequency20 kHz – 100 kHz Acoustic
Leak RateDown to 0.1 bar Pressure Drop
EnvironmentNoisy Industrial Operational Use
Rapid Field Operations

24/7 On-Call Emergency Restoration

Critical infrastructure cannot wait for Monday morning. Skycom maintains rapid-dispatch engineering vans and certified technicians on standby 24 hours a day, 365 days a year.

Guaranteed < 2-Hour Response SLA
Field engineering squads mobilize immediately upon alarm dispatch to contain electrical faults, fiber breaks, or water ingress.
Mobile Tool & Spares Inventory
Fully equipped service vehicles carrying high-voltage personal protective equipment (PPE), portable generators, splice kits, and contactors.
Transparent Digital Incident Tickets
Real-time GPS timestamping, photographic fault evidence, root cause analysis (RCA) reporting, and client sign-off.
Set Up SLA On-Call Contract
24/7 Facilities Emergency Dispatch by Skycom
24/7 NOC Monitored
99.9% Uptime Guarantee
SLA Checkpoint Calculator

Configure Your Maintenance SLA Checkpoints

Adjust asset density and required emergency response tier to estimate required preventative maintenance cycles, thermal scans, and technician dedication.

40 Assets / Units

Estimated Maintenance Operations Scope

4 Cycles / Year
Scheduled PM Audits
4 Scans / Year
FLIR Infrared Scans
2 Techs On-Call
Dedicated Field Crew
99.9% Uptime
Contracted SLA Target

SLA Note: Maintenance cycles include comprehensive electrical, mechanical, optical, and solar sub-system checkpoints with digital CMMS work logs provided after each visit.

Request Custom AMC Agreement & BoQ
Facilities Helpdesk

Request an AMC Maintenance Proposal

Protect your infrastructure investments with customized annual maintenance contracts (AMC), scheduled preventative diagnostics, and 24/7 on-call emergency response across India.

Facilities Consultation Email

helpdesk@skycominfra.in

Email Facilities Desk

Corporate Headquarters

SR 4021/1, T 08, Shop 2, Dattawadi Akurdi, Tarde Bldg, Pune, MH, India

Direct WhatsApp Facilities Desk
Instant technical consultation & AMC scoping

Submit Maintenance Scope

Fill in your facility equipment details for an Annual Maintenance Contract (AMC) proposal.